Registration Dossier

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Test animals / tissue source

Species:
other: Reconstructed Human Cornea-like epithelium (RHCE)

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Duration of treatment / exposure:
6 h
Duration of post- treatment incubation (in vitro):
30 min

Results and discussion

In vitro

Results
Irritation parameter:
other: viability
Value:
101.16
Negative controls validity:
valid
Remarks:
100
Positive controls validity:
valid
Remarks:
39.12
Remarks on result:
no indication of irritation

Applicant's summary and conclusion

Interpretation of results:
other: non irritant