Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
GLP compliance:
yes (incl. certificate)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Particle sizeopen allclose all
Percentile:
D10
Mean:
0.757 µm
Remarks on result:
other: St.dev. not reported
Percentile:
D50
Mean:
2.268 µm
Remarks on result:
other: St.dev. not reported
Percentile:
D90
Mean:
4.597 µm
Remarks on result:
other: St.dev. not reported

Applicant's summary and conclusion