Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2017-08-17 to 2017-11-28
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
consilab Gesellschaft für Anlagensicherheit mbH, Industriepark Höchst, G830/G840, 65926 Frankfurt am Main, Germany
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
3.2 µm
St. dev.:
0
Key result
Percentile:
D50
Mean:
8 µm
St. dev.:
0.14
Percentile:
D90
Mean:
293.5 µm
St. dev.:
15.41
Conclusions:
The test item contains a coarse fraction (>2000 µm) of 66.2 % and a fine fraction (<2000 µm) of 33.8 %. The fine fraction has a median particle size D50 = 8 µm, which was determined by laser diffraction measurement.
Executive summary:

A study was conducted according to OECD TG 110, OPPTS 830.7520 and ISO 13320 to determine the particle size distribution of the test item. The particle size distribution was determined using laser diffraction. Two test series of 3 measurements each were performed with the test item. The test item has a median particle size D50 = 8.0 µm, which was determined by laser diffraction measurement.

Description of key information

The test item contains a coarse fraction (>2000 µm) of 66.2 % and a fine fraction (<2000 µm) of 33.8 %. The fine fraction has a median particle size D50 = 8 µm, which was determined by laser diffraction measurement.

Additional information

A study (reference 4.5-1) was conducted according to OECD TG 110, OPPTS 830.7520 and ISO 13320 to determine the particle size distribution of the test item. The particle size distribution was determined using laser diffraction. Two test series of 3 measurements each were performed with the test item. The test item has a median particle size D50 = 8.0 µm, which was determined by laser diffraction measurement.