Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
density
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 09, 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The study was conducted according to an internationally recognised method, and under GLP. The substance is considered to be adequately characterised. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
adopted 02. Oct. 2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
Council Regulation (EC) No 440/2008 of 30 May 2008
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected on 29 and 30 November 2010 / signed on 11 April 2011
Type of method:
pycnometer method
Key result
Type:
density
Density:
1.01 g/cm³
Temp.:
20 °C
Key result
Type:
relative density
Density:
1.01 other: unitless
Temp.:
20 °C

Table 4.4/1: Measured Values

 

First Determination

Error rel.

Error abs.

Temperature

20.0

°C

 

 

0.1

Density of water

0.998203

g/cm3

 

2.00%

0.0002

Weighing #

m1

m2

m3

 

 

Item

Pycn. empty

Pycn. + H2O

Pycn. + test item

 

 

Mass in g

36.9420

61.8082

62.0950

 

 

Temperature in °C

20.0

20.0

19.8

 

 

Volume of Pycnometer

24.9110

cm3

 

 

 

Density of Test Item

1.0097

g/cm3

 

0.0048%

0.0000

Second Determination

Error rel.

Error abs.

Temperature

20.0

°C

 

 

0.1

Density of water

0.998203

g/cm3

 

2.00%

0.0002

Weighing #

m1

m2

m3

 

 

Item

Pycn. empty

Pycn. + H2O

Pycn. + test item

 

 

Mass in g

36.9419

61.8029

62.0911

 

 

Temperature in °C

20.0

20.0

20.0

 

 

Volume of Pycnometer

24.9058

cm3

 

 

 

Density of Test Item

1.0098

g/cm3

 

0.0048%

0.0000

Results of the single determinations with the respective error as well as the mean value and its standard deviation are presented in the following tables:

 

Table 4.4/2: Results of Single Determinations

 

Determination

Density in g/cm3

Error of Determ. in g/cm3

1

1.0097

0.0000

2

1.0098

0.0000

 

Table 4.4/3 Results – Mean Values

Parameter

Value

Unit

Standard

Deviation

Relative Standard

Deviation

Volume of Pycnometer

24.91

cm3

0.0037

0.01%

Density of Test Item

1.0097

g/ cm3

0.0000

0.00%

Density of Test Item

1009.7

Kg/m3

0.0

0.00%

Relative Density of Test Item

1.0097

 

0.0000

0.00%

The density of the test item was calculated as 1.0097 g/ cm3 at 20.0 ± 0.2 °C, which is the mean of two independent determinations. Standard deviation shows a very good correlation of the two determinations. Therefore, the study is considered valid.

Conclusions:
The density of the test substance was calculated as 1.0097 g/ cm3 at 20.0 ± 0.2 °C and the relative density is determined as D20/4 = 1.0097
Executive summary:

The density of the test substance was measured under GLP according OECD 109 / EU A3 guideline, using the pycnometer method.

Two determinations were performed and the mean value was retained.

This result was then converted to relative density towards water at 4°C.

Mean density: 1.0097g/cm3at 20.0 ± 0.2 °C

Mean relative density (D20/4) : 1.0097

Description of key information

The density of the test item was calculated as 1.0097 g/cm3 at 20.0 ± 0.2 °C and the relative density is determined as D20/4 = 1.0097

Key value for chemical safety assessment

Relative density at 20C:
1.01

Additional information

A fully reliable experimental study, conducted according to a recognized OECD/EC method and under GLP, is available. It is considered as a key study. The result is retained as key data for purpose of CSA.