Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the flash point is only relevant to liquids and low melting point solids
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
According to IU Section 4.2, the melting point of the test substance is 66°C. Therefore it is still solid at the upper classification threshold of 60°C, based on CLP criteria.
The classification of the test item for flammable properties is based on the UN N1 test (see 4.13).
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 15 July 2015 to 30 September 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Study performed according to recognized international guidelines. No deviation from the guideline was observed in the study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
July 27, 1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Version / remarks:
Regulation (EC) 440/2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7200 (Melting Point / Melting Range)
Version / remarks:
March 1998
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
other: differential scanning calorimetry
Specific details on test material used for the study:
4-chloroformylphthalic anhydride
Key result
Melting / freezing pt.:
66 °C

Preliminary test:

The test substance was heated at a rate of 20°C/minute from 25°C to 342°C. At this point, 70% weight loss of the test substance was observed.

Main test:

Three experiments have been performed, under nitrogen and at atmospheric pressure:

 Experiment  1  2  3
 Sample amount (mg)  3.78  3.02 3.42 
Crucible

Aluminium,

pierced

Aluminium,

pierced

Aluminium,

pierced

 Initial temperature (°C)  25 -25  -25
 Rate (°C/min)  20  20  20
 Temperature 2 (°C)  ---  100 --- 
 Rate (°C/min) ---   -5  ---
 Temperature 3 (°C)  ---  -50  ---
 Rate (°C/min)  ---  20  ---
 End temperature (°C)  316  150  150

In experiment 1, an endothermic peak between 50°C and 100°C was observed. The extrapolated onset temperature of the peak could not be determined since it was observed within 2 minutes from the start of the experiment. The effect was most likely obtained due to melting of the test item.

To investigate this peak, a repeated heating cycle was applied in the experiment 2, starting at a lower temperature.

With the first heating phase, the extrapolated onset temperature of the melting peak was 66.25°C.

During cooling, no effects were observed which were due to crystallization of the test substance.

With the second heating, an exothermic peak between 0°C and 50°C was observed. The effect was obtained due to crystallization of the test item. Second heating in combination with cooling provides enough time for test item to crystalize at lower temperatures. Then, a further endothermic effect, due to melting of the test item, was recorded with an extrapolated onset temperature of 65.67°C. This value was not used for calculation of the melting temperature, since it was obtained by melting of non-original test substance. After the experiment, a colourless molten residue remained in the sample container.

Experiment 3 was performed to determine the duplicate melting temperature of the test item. The extrapolated onset of the melting peak was 66.10°C. After the experiment, a colourless molten residue remained in the sample container.

The melting temperature was determined as the average melting temperature obtained from Experiment 2 (66.25°C) and Experiment 3 (66.10°C).

Conclusions:
The melting point of the test item is 66°C.
Executive summary:

The melting point of the test item was determined with Differential Scanning Calorimetry (DSC), according to recognized guidelines (OECD Guideline 102, EU Method A.1 and EPA OPPTS 830.7200) and under GLP. No deviations from the guidelines have been observed during the test.

Two consistent determinations, under nitrogen atmosphere, provided an average melting point of 66°C.

Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 15 July 2015 to 30 September 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Version / remarks:
UN no. ST/SG/AC.10/11/Rev.5, 2009
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
Regulation EC no. 440/2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
4-chloroformylphthalic anhydride
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

In contact with the flame of the gas burner the test item melted, and turned into a black residue. White smoke was observed. After removal of the ignition source, no propagation of combustion of the test item was observed.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item does not propagate combustion in the preliminary test.
Therefore it is NOT considered as a flammable solid, based on GHS and CLP criteria.
Executive summary:

The flammability of the test item was determined according to recognized guidelines (UN N.1, EU A.10)

and under GLP.

No deviation from the guidelines was observed during the test.

The test item did not propagate combustion in the preliminary test.

Therefore it is NOT considered as a flammable solid, based on GHS and CLP criteria.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion