Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

General information

When in doubt or if symptoms are observed, get medical advice. If unconscious place in recovery position and seek

medical advice.

After inhalation

Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial

respiration.

In case of skin contact

Wash immediately with: Water. Do not wash with: Solvents/Thinner. In case of skin reactions, consult a physician.

After eye contact

After contact with the eyes, rinse with water with the eyelids open for a sufficient length of time, then consult an

ophthalmologist immediately.

After ingestion

Do not induce vomiting. Keep at rest. Call a physician immediately.

Self-protection of the first aider

No mouth-to-mouth or mouth-to-nose resuscitation. Use Ambu bag or ventilator.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media

Alcohol resistant foam. Carbon dioxide (CO2). Dry extinguishing powder. Water mist

Unsuitable extinguishing media

High power water jet.

Special hazards arising from the substance or mixture

Hazardous combustion products

In case of fire may be liberated: Carbon monoxide (CO). Carbon dioxide (CO2). Sulphur oxides (SOx). Hydrogen fluoride (HF).

Advice for firefighters

In case of fire: Wear self-contained breathing apparatus.

Special protective equipment for firefighters

In case of fire: Wear self-contained breathing apparatus.

Additional information

Burning produces heavy smoke. Do not allow run-off from fire-fighting to enter drains or water courses.

Accidental release measures

Personal precautions, protective equipment and emergency procedures

Avoid generation of dust. Remove all sources of ignition. Provide adequate ventilation.

Environmental precautions

Do not allow to enter into surface water or drains.

Methods and material for containment and cleaning up

For cleaning up

Take up mechanically. Avoid generation of dust. Collect in closed and suitable containers for disposal. Clean with detergents. Avoid solvent cleaners

Handling and storage

Protective measures

All work processes must always be designed so that the following is excluded: inhalation of dust/particles, skin contact,eye contact, generation/formation of dust. Only use the material in places where open light, fire and other flammable sources can be kept away. After use replace the closing cap immediately. Wear personal protection equipment. Use only in well-ventilated areas.

Fire prevent measures

Keep away from sources of ignition - No smoking. Dust can form an explosive mixture with air. Take precautionary measures against static discharges.

Measures to prevent aerosol and dust generation

Provide adequate ventilation as well as local exhaustion at critical locations.

Conditions for safe storage, including any incompatibilities

Requirements for storage rooms and vessels

Keep container tightly closed. Ensure adequate ventilation of the storage area. Restrict access to stockrooms.

Hints on storage assembly

Storage class : 13

Keep away from

Strong acid. Strong alkali. Oxidising agent.

Further information on storage conditions

Keep only in the original container in a cool, well-ventilated place.

Protect against : Heat. UV-radiation/sunlight. Humidity.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
No dangerous good in sense of transport regulation.
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
No dangerous good in sense of transport regulation.
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
No dangerous good in sense of transport regulation.
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
No dangerous good in sense of transport regulation.
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Eye / face protection

Eye glasses with side protection

Remark

Do not wear contact lenses.

Skin protection

Hand protection

The quality of the protective gloves resistant to chemicals must be chosen as a function of the specific working place

concentration and quantity of hazardous substances.

Required properties : Antistatic, dust-tight.

Additional hand protection measures : Check leak tightness / impermeability prior to use. Do not wear gloves

near rotary machines and tools. Use gloves only once.

Remark : For special purposes, it is recommended to check the resistance to chemicals of the protective gloves

mentioned above together with the supplier of these gloves.

Body protection

For the protection against direct skin contact, body protective clothing is essential (in addition to the usual working

clothes).

Suitable protective clothing : Overall.

Required properties : Antistatic.

Remark : Only wear fitting, comfortable and clean protective clothing. Barrier creams are not substitutes for body

protection.

Respiratory protection

If technical exhaust or ventilation measures are not possible or insufficient, respiratory protection must be worn.

Respiratory protection necessary at: exceeding exposure limit values, handling larger quantities, dust formation.

Remark

The filter class must be suitable for the maximum contaminant concentration (gas/vapour/aerosol/particulates) that

may arise when handling the product. If the concentration is exceeded, self-contained breathing apparatus must be

used.

General health and safety measures

Wash hands before breaks and after work. When using do not eat, drink, smoke, sniff. Wash contaminated clothing

prior to re-use. Thorough skin-cleansing after handling the product.

Additional information

Preventive industrial medical examinations are to be offered.

Stability and reactivity

Reactivity

No information available.

Chemical stability

No information available.

Possibility of hazardous reactions

No information available.

Conditions to avoid

Stable under recommended storage and handling conditions.

Incompatible materials

Keep away from oxidizing agents, strongly alkaline and strongly acid materials in order to avoid exothermic reactions.

Hazardous decomposition products

When exposed to high temperatures may produce hazardous decomposition products such as carbon monoxide and

dioxide, smoke, oxides of nitrogen.

Disposal considerations

Waste treatment methods

Product/Packaging disposal

Waste treatment options

Appropriate disposal / Product

Waste disposal according to EC directives 75/442/EEC and 91/689/EEC in the corresponding versions, covering

waste and dangerous waste.

Appropriate disposal / Package

Contaminated packages must be completely emptied and can be re-used following proper cleaning. Handle

contaminated packages in the same way as the substance itself.