Registration Dossier

Administrative data

Endpoint:
flammability, other
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: crystalline

Results and discussion

Any other information on results incl. tables

Phenomena and results from two independent preliminary screening tests, were identical as following:

- the sample was ignited within 2 min;

- after removal of ignition, the sample didn’t propagate combustion either by burning with flame or smouldering along 200 mm of the train within the 4 min.

Applicant's summary and conclusion

Conclusions:
The sample is not a highly flammable solid.