Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 16.09.2016 to 20.10.2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
1,1'-(1,3-phenylene)bis-1H-pyrrole-2,5-dione
EC Number:
221-112-8
EC Name:
1,1'-(1,3-phenylene)bis-1H-pyrrole-2,5-dione
Cas Number:
3006-93-7
Molecular formula:
C14H8N2O4
IUPAC Name:
1,1'-(1,3-phenylene)bis-1H-pyrrole-2,5-dione
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Xianyang Sanjing Technology Co., ltd./160612
- Expiration date of the lot/batch: June 18, 2018
- Purity: > 99.6 % w/w


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature, in a cool and dry place, away from light

Test animals / tissue source

Species:
cattle
Details on test animals or tissues and environmental conditions:
TEST ANIMALS
- Source:Bovine eyes - Breeding service CHOVSERVIS a.s., division TORO® Hlavečník, Hradec Králové, Czech Republic


Test system

Vehicle:
other: 0.9% sodium chloride solution
Controls:
yes, concurrent vehicle
yes, concurrent positive control
Amount / concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 750 µL per cornea (2g of the test substance was suspended in 10 mL of 0.9% sodium chloride solution).
- Concentration (if solution): 20%

VEHICLE
- Amount(s) applied (volume or weight with unit): 750 µL
- Concentration (if solution): 0.9% sodium chloride solution
- Lot/batch no. (if required): 15/M422A1
Duration of treatment / exposure:
4 hours
Number of animals or in vitro replicates:
3 per group
Details on study design:
SELECTION AND PREPARATION OF CORNEAS:
Eyes were collected by slaughterhouse employees. The eyes were enucleated as soon as possible after death. No detergent was used. Only healthy animals (12 to 30 months old) considered suitable for entry into the human food chain were used as a source of corneas for use in the BCOP test. The risk of contamination was minimized (e.g., by keeping the container containing the eyes on ice, by adding antibiotics to the HBSS used to store the eyes during transport (e.g., penicillin at 100 IU/mL and streptomycin at 100 μg/mL). The time interval between collection of the eyes and use of corneas in the BCOP was minimized (collected and used on the same day). The results were based on the selection criteria for the eyes, as well as the positive and negative control responses. All eyes used in the assay were from the same group of eyes collected on a specific day.

Corneas free of defects were dissected with a 2 to 3 mm rim of sclera remaining to assist in subsequent handling, with care taken to avoid damage to the corneal epithelium. Isolated corneas were mounted in specially designed corneal holders that consisted of anterior and posterior compartments, which interfaced with the epithelial and endothelial sides of the cornea, respectively. Both chambers were filled to excess with pre-warmed Eagle's Minimum Essential Medium (EMEM). The device was then equilibrated at 32 ± 1°C for at least one hour in water bath to allow the corneas to equilibrate with the medium and to achieve normal metabolic activity, to the extent possible. Following the equilibration period, fresh pre-warmed EMEM was added to both chambers and baseline opacity readings were taken for each cornea. Any corneas that showed macroscopic tissue damage (e.g., scratches, pigmentation, neovascularization) or an opacity >7 opacity units were discarded. Each test group (test substance, concurrent negative and positive controls) consisted of the three eyes. The three corneas with opacity values close to the median value for all corneas were selected as negative control corneas. The remaining corneas were then distributed into treatment and positive control groups.


QUALITY CHECK OF THE ISOLATED CORNEAS:
The eyes, once they arrive at the laboratory, were carefully examined for defects including scratched, and neovascularisation. Only corneas from eyes free of such defects were used. The isolated corneas, after achieve normal metabolic activity (inductive incubation at 32 ± 1°C for one hour), were examined again. The corneas that show macroscopic tissue damage (e.g., scratches, pigmentation, neovascularization) or a baseline opacity >7 opacity units were discarded. From 25 eyes the 5 eyes were eliminated after inductive incubation, because the baseline opacity values were >7. Nine corneas were used for the study (the corneas No. 1, 2, 3, 4, 5, 6, 7, 8 and 9), 8 eyes were superfluous and the remaining 3 eyes were used for the testing of another substance.

NUMBER OF REPLICATES: 3

NEGATIVE CONTROL USED: 0.9% NaCl

POSITIVE CONTROL USED: 20% Imidazole in 0.9% NaCl

APPLICATION DOSE AND EXPOSURE TIME: As a non-surfactant solid, the test substance was tested at 20% concentration in a 0.9% sodium chloride solution for 4 hours.

TREATMENT METHOD: Closed-chamber method was used, because the test substance was applicable by micropipette. The test substance (750 µL of application form) to cover the epithelial side of the cornea is introduced into the anterior chamber through the dosing holes on the top surface of the chamber, and the holes were subsequently sealed with the chamber plugs during the exposure.

POST-INCUBATION PERIOD: No, substance is a solid.

REMOVAL OF TEST SUBSTANCE
- Number of washing steps after exposure period: Once with EMEM (containing phenol red) and once with EMEM alone.

- POST-EXPOSURE INCUBATION: The anterior chamber was then refilled with fresh EMEM without phenol red. The opacity and permeability of each cornea were recorded.

METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: Corneal opacity was measured quantitatively with the aid of an opacitometer (Opacitometer, MC2 - Le spécialiste du laboratoire – France) resulting in opacity values measured on a continuous scale
- Corneal permeability: 1 mL sodium fluorescein solution (5 mg/mL) was added to the anterior chamber of the corneal holder, which interfaced with the epithelial side of the cornea, while the posterior chamber, which interfaced with the endothelial side of the cornea, is filled with fresh EMEM. The holder was incubated in horizontal position for 1.5 hours at 32 ± 1 ºC. The amount of sodium fluorescein that crosses into the posterior chamber was quantitatively measured with the aid of UV/VIS spectrophotometry (Spectrophotometer GENESYSTM 10 UV/VIS Scanning). The values of absorbance measured at 490 nm were recorded as optical density (OD490) values. This term was used because the measuring is performed with visible light spectrophotometer using a standard 1 cm path length

- Others (e.g, pertinent visual observations, histopathology): (please specify)

SCORING SYSTEM: IVIS = mean opacity value + (15 x mean permeability OD490 value)

DECISION CRITERIA: A test is considered acceptable if the positive control gives IVIS that falls within one standard deviations of the current historical mean, which is to be updated at least every three months, or each time an acceptable test is conducted in laboratories where tests are conducted infrequently. The negative or solvent/vehicle control responses should result in opacity and permeability values that are less than the established upper limits for background opacity and permeability values for bovine corneas treated with the respective negative or solvent/vehicle control.

Results and discussion

In vitro

Resultsopen allclose all
Irritation parameter:
cornea opacity score
Value:
0.33
Vehicle controls validity:
valid
Negative controls validity:
not applicable
Positive controls validity:
valid
Remarks:
51
Irritation parameter:
fluorescein leakage
Value:
0.002
Vehicle controls validity:
valid
Negative controls validity:
not applicable
Positive controls validity:
valid
Remarks:
1.884
Irritation parameter:
in vitro irritation score
Value:
0.36
Vehicle controls validity:
valid
Remarks:
1.15
Negative controls validity:
not applicable
Positive controls validity:
valid
Remarks:
79.26
Other effects / acceptance of results:
OTHER EFFECTS:
- Visible damage on test system: Appearance of corneas was observed before and after application of the test substance, negative and positive control (see Tables 2 and 3). No macroscopic damage was observed on corneas before application. Corneal opacity was observed on the corneas treated by positive control. The corneas treated by negative control were without macroscopic damage. The corneas treated by the test substance were without macroscopic damage.


ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: The value of opacity for the negative control (0.9% NaCl) obtained during the study was 1.00 and the value of permeability was 0.010. The values obtained during this study did not exceed the upper limits of the historical controls (1.81 and 0.0714 from 36 studies), so the study is considered acceptable.

- Acceptance criteria met for positive control: The value of IVIS for positive control (20% imidazole) obtained during the study was 79.26. This value is within the acceptance limit (one standard deviations (6.93) of the current historical mean of 30 studies), so the study is considered acceptable

Any other information on results incl. tables

Decision criteria

The IVIS cut-off value for identifying the test substance as including serious eye damage (UN GHS Category 1) and the test substance not requiring classification for eye irritation or serious damage (UN GHS No Category) is given in the table below:

IVIS

UN GHS

≤ 3

No Category

>3; ≤ 55

No prediction can be made

≥ 55

Category 1

UN GHS Category 1: “Serious eye damage”

UN GHS Category 2: “Eye irritation”

UN GHS No Category: Chemicals that do not meet the requirements for classification as: UN GHS Category 1 or 2. Interchangeable with “Not Classified"

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
In the Bovine Corneal Opacity and Permeability (BCOP) assay, the IVIS for N,N′-m-phenylenedimaleimide was 0.36. As the IVIS is ≤ 3, the classification of the test substance according to UN GHS criteria for eye irritation or serious eye damage is: No category.
Executive summary:

In the Bovine Corneal Opacity and Permeability (BCOP) assay (16-566), isolated bovine corneas were exposed to 20% N,N′-m-phenylenedimaleimide in 0.9% NaCl for 4 hours using the closed chamber method. 0.9% NaCl was used for the negative control and 20% Imidazole in 0.9% NaCl was used for the positive control. The corneas were rinsed twice and the opacity and permeability (via sodium fluorescein dye) of each cornea were recorded.

There was no macroscopic damage to any corneas treated with the test substance. The mean opacity value and mean permeability OD490 for the test substance were 0.33 and 0.002 respectively. The IVIS for the test substance was 0.36. The positive control gave the appropriate response. The IVIS for N,N′-m-phenylenedimaleimide is ≤ 3 and the classification of the test substance according to UN GHS criteria for eye irritation or serious eye damage is: No category.

This Bovine Corneal Opacity and Permeability (BCOP) is acceptable and satisfies the guideline requirement for an OECD 437 study.