Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-03-09 – 2017-03-09
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental result performed using standard methods of analysis
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Principles of method if other than guideline:
Measurement of resistance to flow using Redwood Viscometer No. 1.

GLP compliance:
no
Type of method:
other: Redwood Viscometer No. 1
Specific details on test material used for the study:
- IUPAC name: 9,10-Anthracenedione, 1,4-diamino-, N,N'-bis(4-C7-17-branched alkylphenyl) derivs.
- Substance type: Organic
- Physical state: Liquid
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
414.96
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
355.68
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
405.706
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
347.748

Method Details

Observations

Remarks if, any

Guideline

OECD 114

 

Method of

measurement

Redwood Viscometer No. -1

 

Principle of method

The flow of chemical under gravity through a capillary using Redwood Viscometer No. 1

 

Temperature at which

the testing is done

20°C and 40°C

 

Observations

Time taken to fill 50ml flask at

20°C in ‘Sec’ (Mean Value)

1680 sec

 

Time taken to fill 50ml at 40°C

flask in ‘Sec’ (Mean Value)

1440 sec

 

Density of fluid in gm/cc

0.9777 gm/cc

 

CALCULATIONS:

ν= ct----------------------------------------- (i)

Where,ν= Kinematic viscosity

c= Viscometer constant

t= time of flow in seconds (Redwood second) For Redwood Viscometer- I, the values for the constants are as

below:

 

Time of flow, t

C

40 to 85 seconds

0.264

85 to 2000

0.247

 

ν=η/ρ------------------------------ (ii)

Where,ν= Kinematic viscosity

η= Dynamic viscosity

ρ= Density of fluid

1. Calculation of Kinematic Viscosities:

 

For Test Temperature at 20°C

ν=ct

= 1680 × 0.247sec

= 414.9600mm²/sec

 

For Test Temperature at 40°C

ν=ct

= 1440 × 0.247sec

= 355.6800 mm²/sec

 

2. Calculation of Dynamic Viscosities:

For Test Temperature at 20°C

ν= η/ρ

414.9600 =η 0.9777

η = 414.9600 x 0.9777

= 405.7063 mPa.S

 

For Test Temperature at 40°C

ν= η/ρ

355.6800 =η/ 0.9777

η = 355.6800 x 0.9777

= 347.7483 mPa.S

Conclusions:
Kinematic viscosity (experimental) of 9,10-Anthracenedione, 1,4-diamino-, N,N'-bis(4-C7-17-branched alkylphenyl) derivs.( CAS No. 97862-23-2)at 20°C and 40°C is 414.9600mm²/secand 355.6800mm²/s,respectively.
Dynamic viscosity (calculated) of 9,10-Anthracenedione, 1,4-diamino-, N,N'-bis(4-C7-17-branched alkylphenyl) derivs.( CAS No. 97862-23-2)at 20°C and 40°C is 405.7063mPa.Sand 347.7483mPa.S,respectively.
Executive summary:

The viscosity determination of Test item 9,10-Anthracenedione, 1,4-diamino-, N,N'-bis(4-C7-17-branched alkylphenyl) derivs. (CAS No. 97862-23-2 )was done as per the test guideline OECD 114 using Redwood Viscometer No. 1. Kinematic viscosity (experimental) of Test item at 20°C and 40°C is 414.9600 mm²/sec and 355.6800 mm²/s, respectively. Dynamic viscosity (calculated) of Test item at 20°C and 40°C is 405.7063 mPa.S and 347.7483 mPa.S, respectively.

Description of key information

The viscosity determination of Test item 9,10-Anthracenedione, 1,4-diamino-, N,N'-bis(4-C7-17-branched alkylphenyl) derivs. (CAS No. 97862-23-2 )was done as per the test guideline OECD 114 using Redwood Viscometer No. 1. Kinematic viscosity (experimental) of Test item at 20°C and 40°C is 414.9600 mm²/sec and 355.6800 mm²/s, respectively. Dynamic viscosity (calculated) of Test item at 20°C and 40°C is 405.7063 mPa.S and 347.7483 mPa.S, respectively.

Key value for chemical safety assessment

Viscosity:
405.706 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

The viscosity determination of Test item 9,10-Anthracenedione, 1,4-diamino-, N,N'-bis(4-C7-17-branched alkylphenyl) derivs. (CAS No. 97862-23-2 )was done as per the test guideline OECD 114 using Redwood Viscometer No. 1. Kinematic viscosity (experimental) of Test item at 20°C and 40°C is 414.9600 mm²/sec and 355.6800 mm²/s, respectively. Dynamic viscosity (calculated) of Test item at 20°C and 40°C is 405.7063 mPa.S and 347.7483 mPa.S, respectively.