Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 618-347-7 | CAS number: 9003-01-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
Information was obtained from read-across from supporting substance (acrylic acid) which is of moderate toxicity after a single ingestion and after short-term inhalation exposure. Acrylic acid is not toxic after short-term skin contact, when tested in non-corrosive concentrations.
- Oral: LD50 = 1500 mg/kg or 146-1405 mg/kg bw (rat) depending on the concentration tested
- Dermal: LD50 > 2000 mg/kg bw (rabbit, occlusive)
- Inhalation: LC50 > 5.1 mg/L (rat, vapour saturated atmosphere)
Key value for chemical safety assessment
Acute toxicity: via oral route
Link to relevant study records
- Endpoint:
- acute toxicity: oral
- Type of information:
- read-across from supporting substance (structural analogue or surrogate)
- Adequacy of study:
- weight of evidence
- Justification for type of information:
- 1. HYPOTHESIS FOR THE ANALOGUE APPROACH
- Read-across hypothesis: "Different compounds have the same type of effect(s)"
2. SOURCE AND TARGET CHEMICAL(S) (INCLUDING INFORMATION ON PURITY AND IMPURITIES)
- Target chemical: 2-Propenoic acid, homopolymer (purity ≥ 99.0%) = UVCB substance composed of acrylic acid monomers (Mw = 72 g/mol) and 2-carboxyethyl acrylate oligomers (average Mw = 208.8 g/mol)
- Source chemical: Acrylic acid = monoconstituent substance composed of acrylic acid monomers (Mw = 72 g/mol)
3. ANALOGUE APPROACH JUSTIFICATION
- Common structure: the constituents of the target and source chemicals share identical functional groups (i.e. one terminal carboxylic acid group and one terminal vinyl group) and only differ in the presence/absence of one or several -CH2-CH2-COO- pattern(s) in their structural backbones. This pattern being introduced as a result of (poly)addition reactions, it is only present in the polymerized units of acrylic acid (average number of -CH2-CH2-COO- patterns per vinyl group: < 3) and is absent from the monomer units.
- Common physico-chemical/fate properties: the target and source chemicals are both hydrophylic substances (log Pow < 1) with a high solubility in water and a low volatility (VP < 5 hPa). Both substances have a low potential for bioaccumulation in living organisms (log Pow < 4) and a low potential for persistence in environmental compartments (rapidly degradable).
- Common mode of action: the toxic effects of the target and source chemicals are expected to result from their acidic character (carboxylic acid group) and from the reactivity of their double bond (vinyl group). As the polyaddition reactions lead only to an increase in the chain length/molecular weight without an increase in the number of reactive functional groups, the low molecular-weight polymerized units of acrylic acid (from the test item) are not expected to exert higher toxicity than the monomer units. As a result, the target chemical, although only partially composed of acrylic acid monomers, is considered at the very worst to be as toxic as the source substance.
Further information (including data matrix) is available in the attached read-across justification document. - Reason / purpose for cross-reference:
- read-across source
- Reason / purpose for cross-reference:
- read-across source
- Reason / purpose for cross-reference:
- read-across source
- Key result
- Sex:
- male/female
- Dose descriptor:
- LD50
- Effect level:
- >= 146 - <= 1 500 mg/kg bw
- Based on:
- act. ingr.
- Interpretation of results:
- Category 4 based on GHS criteria
- Conclusions:
- When administered orally to rats, the LD50 of the analogue acrylic acid ranged between 146 and 1500 mg/kg, depending on the concentration tested, the gender and the animal strain. Overall, the experimentally obtained acute oral toxicity values are consistent with the classification of the registered substance in category 4 according to the UN-GHS criteria.
Reference
Endpoint conclusion
- Endpoint conclusion:
- adverse effect observed
- Dose descriptor:
- LD50
- Value:
- 1 500 mg/kg bw
- Quality of whole database:
- Acceptable with restrictions
Acute toxicity: via inhalation route
Link to relevant study records
- Endpoint:
- acute toxicity: inhalation
- Type of information:
- read-across from supporting substance (structural analogue or surrogate)
- Adequacy of study:
- key study
- Justification for type of information:
- 1. HYPOTHESIS FOR THE ANALOGUE APPROACH
- Read-across hypothesis: "Different compounds have the same type of effect(s)"
2. SOURCE AND TARGET CHEMICAL(S) (INCLUDING INFORMATION ON PURITY AND IMPURITIES)
- Target chemical: 2-Propenoic acid, homopolymer (purity ≥ 99.0%) = UVCB substance composed of acrylic acid monomers (Mw = 72 g/mol) and 2-carboxyethyl acrylate oligomers (average Mw = 208.8 g/mol)
- Source chemical: Acrylic acid = monoconstituent substance composed of acrylic acid monomers (Mw = 72 g/mol)
3. ANALOGUE APPROACH JUSTIFICATION
- Common structure: the constituents of the target and source chemicals share identical functional groups (i.e. one terminal carboxylic acid group and one terminal vinyl group) and only differ in the presence/absence of one or several -CH2-CH2-COO- pattern(s) in their structural backbones. This pattern being introduced as a result of (poly)addition reactions, it is only present in the polymerized units of acrylic acid (average number of -CH2-CH2-COO- patterns per vinyl group: < 3) and is absent from the monomer units.
- Common physico-chemical/fate properties: the target and source chemicals are both hydrophylic substances (log Pow < 1) with a high solubility in water and a low volatility (VP < 5 hPa). Both substances have a low potential for bioaccumulation in living organisms (log Pow < 4) and a low potential for persistence in environmental compartments (rapidly degradable).
- Common mode of action: the toxic effects of the target and source chemicals are expected to result from their acidic character (carboxylic acid group) and from the reactivity of their double bond (vinyl group). As the polyaddition reactions lead only to an increase in the chain length/molecular weight without an increase in the number of reactive functional groups, the low molecular-weight polymerized units of acrylic acid (from the test item) are not expected to exert higher toxicity than the monomer units. As a result, the target chemical, although only partially composed of acrylic acid monomers, is considered at the very worst to be as toxic as the source substance.
Further information (including data matrix) is available in the attached read-across justification document. - Reason / purpose for cross-reference:
- read-across source
- Key result
- Sex:
- male/female
- Dose descriptor:
- LC50
- Effect level:
- > 5.1 mg/L air
- Based on:
- act. ingr.
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- When exposing rats to vapours, the LC50 of the analogue acrylic acid was strictly above 5.1 mg/L. Based on the absence of mortality or signs of overt toxicity at this concentration, the experimentally obtained acute inhalation toxicity values are consistent with the absence of classification of the registered substance according to the UN-GHS criteria.
Reference
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed
- Quality of whole database:
- Acceptable with restrictions
Acute toxicity: via dermal route
Link to relevant study records
- Endpoint:
- acute toxicity: dermal
- Type of information:
- read-across from supporting substance (structural analogue or surrogate)
- Adequacy of study:
- key study
- Justification for type of information:
- 1. HYPOTHESIS FOR THE ANALOGUE APPROACH
- Read-across hypothesis: "Different compounds have the same type of effect(s)"
2. SOURCE AND TARGET CHEMICAL(S) (INCLUDING INFORMATION ON PURITY AND IMPURITIES)
- Target chemical: 2-Propenoic acid, homopolymer (purity ≥ 99.0%) = UVCB substance composed of acrylic acid monomers (Mw = 72 g/mol) and 2-carboxyethyl acrylate oligomers (average Mw = 208.8 g/mol)
- Source chemical: Acrylic acid = monoconstituent substance composed of acrylic acid monomers (Mw = 72 g/mol)
3. ANALOGUE APPROACH JUSTIFICATION
- Common structure: the constituents of the target and source chemicals share identical functional groups (i.e. one terminal carboxylic acid group and one terminal vinyl group) and only differ in the presence/absence of one or several -CH2-CH2-COO- pattern(s) in their structural backbones. This pattern being introduced as a result of (poly)addition reactions, it is only present in the polymerized units of acrylic acid (average number of -CH2-CH2-COO- patterns per vinyl group: < 3) and is absent from the monomer units.
- Common physico-chemical/fate properties: the target and source chemicals are both hydrophylic substances (log Pow < 1) with a high solubility in water and a low volatility (VP < 5 hPa). Both substances have a low potential for bioaccumulation in living organisms (log Pow < 4) and a low potential for persistence in environmental compartments (rapidly degradable).
- Common mode of action: the toxic effects of the target and source chemicals are expected to result from their acidic character (carboxylic acid group) and from the reactivity of their double bond (vinyl group). As the polyaddition reactions lead only to an increase in the chain length/molecular weight without an increase in the number of reactive functional groups, the low molecular-weight polymerized units of acrylic acid (from the test item) are not expected to exert higher toxicity than the monomer units. As a result, the target chemical, although only partially composed of acrylic acid monomers, is considered at the very worst to be as toxic as the source substance.
Further information (including data matrix) is available in the attached read-across justification document. - Reason / purpose for cross-reference:
- read-across source
- Key result
- Sex:
- male/female
- Dose descriptor:
- LD50
- Effect level:
- > 2 000 mg/kg bw
- Based on:
- act. ingr.
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- When exposing rabbits by occlusive dermal application, the LD50 of the analogue acrylic acid was strictly above 2000 mg/kg. Based on the absence of mortality or signs of overt toxicity at this dose, the experimentally obtained acute dermal toxicity value is consistent with the absence of classification of the registered substance according to the UN-GHS criteria.
Reference
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed
Additional information
Justification for classification or non-classification
Based on the LD50/LC50 values obtained with the analogue acrylic acid, the registered substance is classified as Acute Tox. 4, H302 (oral route). The official classification of acrylic acid for acute inhalation and dermal toxicity (H312/H332) is considered not to be relevant to the registered substance.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.