Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
not specified
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Lot: W17061205
Key result
Flash point:
> 93 °C
Remarks on result:
no flash point according to standard method
Remarks:
No flash detected
Interpretation of results:
GHS criteria not met

Description of key information

No flash observed during the test. Flash point >200 F (93 C)

Key value for chemical safety assessment

Additional information