Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 283-130-2 | CAS number: 84540-37-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation, other
- Remarks:
- in vivo study
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- April 22 until April 29, 1996
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 1 996
- Report date:
- 1996
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 405 (Acute Eye Irritation / Corrosion)
- Version / remarks:
- OECD 1981, updated Guideline adopted Februaty 24, 1987
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- 1,1'-Biphenyl, 4-(trans-4-ethylcyclohexyl)-2,3',4',5'-tetrafluoro-
- EC Number:
- 605-735-6
- Cas Number:
- 174805-87-9
- Molecular formula:
- C20 H20 F4
- IUPAC Name:
- 1,1'-Biphenyl, 4-(trans-4-ethylcyclohexyl)-2,3',4',5'-tetrafluoro-
- Test material form:
- solid
Constituent 1
- Specific details on test material used for the study:
- Name: ZLI-4603
Consistency: Crystals
Batch: E96635863
Released until: Feb 28, 1998
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
The test material was moistened with liquid paraffin.
Test animals / tissue source
- Species:
- rabbit
- Strain:
- New Zealand White
- Details on test animals or tissues and environmental conditions:
- TEST ANIMALS
- Source: SAVO-Ivanovas, Kißlegg
- Age at study initiation: about 28-29 weeks
- Weight at study initiation:4.31 (3.94 - 5.00) kg
- Housing: separately in special rabbit cages (manufacturer: Hulskamp, type KK 017)
- Diet (e.g. ad libitum): ad libitum
- Water (e.g. ad libitum): ad libitum
- Acclimation period: more than 7 days
ENVIRONMENTAL CONDITIONS
- Temperature (°C): 20 - 21°C
- Humidity (%): 41 - 53%
IN-LIFE DATES: From: day 1 To: day 8
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- not required
- Amount / concentration applied:
- 0.1g per animal
- Observation period (in vivo):
- 24, 48, and 72 hours, then daily up to day 8 of the experimental part
- Number of animals or in vitro replicates:
- 3 (1 male & 2 female)
- Details on study design:
- REMOVAL OF TEST SUBSTANCE
- Washing (if done): no
SCORING SYSTEM: according OECD-Guideline
TOOL USED TO ASSESS SCORE: hand-slit lamp / fluorescein
Results and discussion
In vivo
Resultsopen allclose all
- Irritation parameter:
- cornea opacity score
- Basis:
- mean
- Time point:
- 24 h
- Score:
- 0
- Max. score:
- 0
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- cornea opacity score
- Basis:
- mean
- Time point:
- 48 h
- Score:
- 0
- Max. score:
- 0
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- cornea opacity score
- Basis:
- mean
- Time point:
- 72 h
- Score:
- 0
- Max. score:
- 0
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- iris score
- Basis:
- mean
- Time point:
- 24 h
- Score:
- 0
- Max. score:
- 0
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- iris score
- Basis:
- mean
- Time point:
- 48 h
- Score:
- 0
- Max. score:
- 0
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- iris score
- Basis:
- mean
- Time point:
- 72 h
- Score:
- 0
- Max. score:
- 0
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- conjunctivae score
- Basis:
- mean
- Time point:
- 24 h
- Score:
- 1
- Max. score:
- 1
- Reversibility:
- fully reversible
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- conjunctivae score
- Basis:
- mean
- Time point:
- 48 h
- Score:
- 0
- Max. score:
- 0
- Remarks on result:
- no indication of irritation
- Irritation parameter:
- conjunctivae score
- Basis:
- mean
- Time point:
- 72 h
- Score:
- 0
- Max. score:
- 0
- Remarks on result:
- no indication of irritation
- Irritant / corrosive response data:
- In the primary eye irritation test, no abnormalities of the cornea and iris were observed. The conjunctivae showed redness (score 1) in all animals at 24h . Later on no abnormalities were seen.
- Other effects:
- none
Any other information on results incl. tables
Study design
To test for primary eye
irritation, the test material was instilled into the conjunctival say of
rabbits. The first examination of the treated eye followed 1 hour after
instillation. The examinations were performed daily for further 7 days.
Results
In the primary eye irritation test, no abnormalities of the cornea and iris were observed. The conjunctivae showed redness (score 1) in all animals at 24h. Later on no abnormalities were seen.
Conclusion
According to these results, for regulatory purposes the test material has to be classified as non-irritant for the eyes.
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- According to these results, for regulatory purposes there is no need for classification for eye irritation.
- Executive summary:
The study was performed according to OECD 405 under GLP conditions. According to these results, for regulatory purposes there is no need for classification for eye irritation.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.