Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
UN Recommendation on the Transport of Dangerous Goods
Deviations:
yes
Remarks:
In the preliminary screening test as ignition source a glowing platinum wire was used instead of gas flame.
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Details on test material:
Test item: N-(2-HYDROXYETHYL) PHTHALIMIDE
CAS No.: 3891-07-4
Physical state: solid, powder
Colour and Odour: white, odourless
Active Ingredient Content (TLC): 98.95 %
Storage: on dry place, protected from light, 15-30 °C

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: Brief ignition and rapid extinction. The flame does not propagate, so the burning rate test was not performed.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information Brief ignition and rapid extinction.
Conclusions:
Brief ignition and rapid extinction. The flame does not propagate. The test substance should not be considered as flammable and no further testing is required. Based on this results obtained, the test substance is considered "non flammable".