Administrative data

First-aid measures

Inhalation
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

Skin
Wash off with soap and plenty of water. Consult a physician.

Eye
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

Ingestion
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Most important, both acute and delayed effects To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated.

Indication of any immediate medical attention and special treatment needed There is no information available

Fire-fighting measures

Extinguishing media Water spray, alcohol-resistant foam, carbon dioxide, dry chemical

Special hazards arising from the substance Carbon oxides, nitrogen oxides (NOx)

Advice for firefighters Wear self contained breathing apparatus for fire fighting if necessary.

Avoid rejection of extinguishing water into drainage system, surface or ground water.

Accidental release measures

Personal precautions, protective equipment and emergency procedures Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.

Enviromental precautions Do not let product enter drains.

Methods for cleaning up, taking up Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.

Handling and storage

Handling and Storage

Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed. Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
not dangerous goods
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Components with workplace: Contains no substances with occupational exposure limit values.

Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

Personal protective equipment
Eye/face protection
Safety glasses with side shields conforming to EN 166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166 (EU).

Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.

The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Body Protection
impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Control of environmental exposure
On the basis of the available information is not required for the environmental exposure controls

Stability and reactivity


Reactivity No data available

Chemical stability No data available

Hazardous decomposition products No data available

Possibility of hazardous reactions Data not available

Conditions to avoid No data available

Incompatible materials Strong oxidizing agents

Materials to avoid No data available

Disposal considerations

Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.

Contaminated packaging
Dispose of as unused product.