Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Qualifier:
according to guideline
Guideline:
other: DIN 66165
Principles of method if other than guideline:
The particle size distribution was determined according to DIN 66165: "Particle size analysis - Sieving analysis ".
GLP compliance:
no
Type of method:
sieving
No.:
#1
Size:
> 2 000 µm
Distribution:
0 %
No.:
#1
Size:
> 1 400 µm
Distribution:
0 %
No.:
#1
Size:
> 1 000 - <= 1 400 µm
Distribution:
0.1 %
No.:
#1
Size:
> 800 - <= 1 000 µm
Distribution:
0.2 %
No.:
#1
Size:
> 500 - <= 800 µm
Distribution:
9.8 %
No.:
#1
Size:
> 400 - <= 500 µm
Distribution:
23 %
No.:
#1
Size:
> 300 - <= 400 µm
Distribution:
36.4 %
No.:
#1
Size:
> 200 - <= 300 µm
Distribution:
22.7 %
No.:
#1
Size:
> 100 - <= 200 µm
Distribution:
7.3 %
No.:
#1
Size:
> 50 - <= 100 µm
Distribution:
0.5 %
No.:
#1
Size:
<= 50 µm
Distribution:
0 %

Description of key information

The particle size distribution was determined according to DIN 66165: "Particle size analysis - Sieving analysis ":

Size of the sieve

%

>1.4 mm

0.0

>1 mm

0.1

>800 µm

0.2

>500 µm

9.8

>400 µm

23.0

>300 µm

36.4

>200 µm

22.7

>100 µm

7.3

>50 µm

0.5

<50 µm

0.0

Additional information