Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 230-811-7 | CAS number: 7328-17-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 03.05.2017-23.05.2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
- GLP compliance:
- yes (incl. QA statement)
- Analytical monitoring:
- no
- Details on sampling:
- No analysis was carried out to determine the homogeneity, concentration or stability of the test item formulation. This exception is considered not to affect the purpose or integrity of the study.
- Vehicle:
- not specified
- Test organisms (species):
- activated sludge, domestic
- Details on inoculum:
- A mixed population of activated sewage sludge micro-organisms was obtained on 3 April 2017 for the range-finding test and on 22 May 2017 for the definitive test from the aeration stage of the Severn Trent Water Plc sewage treatment plant at Loughborough, Leicestershire, UK which treats predominantly domestic sewage.
- Test type:
- static
- Water media type:
- other: The test water used for the range-finding and definitive tests was deionized reverse osmosis water containing less than 1 mg/L Dissolved Organic Carbon (DOC).
- Limit test:
- no
- Total exposure duration:
- 30 min
- Post exposure observation period:
- na
- Test temperature:
- 21C
- pH:
- 7.5-8
- Dissolved oxygen:
- 5.4-6.7 mg/L
- Nominal and measured concentrations:
- Based on the results of the range-finding test the following test concentrations were assigned to the definitive test: 180, 320, 560, 1000 and 1800 mg/L.
- Reference substance (positive control):
- yes
- Remarks:
- 3,5-dichlorophenol
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- 770 mg/L
- Nominal / measured:
- meas. (not specified)
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Results with reference substance (positive control):
- The reference item gave a 3-Hour EC50 value of 5.3 mg/L, 95% confidence limits 3.8 to 7.3 mg/L.
- Validity criteria fulfilled:
- yes
- Conclusions:
- The effect of the test item on the respiration of activated sewage sludge gave a 3-Hour EC50 value of 770 mg/L.
- Executive summary:
A study was performed to assess the effect of the test item on the respiration of activated sewage sludge. The method followed was designed to be compatible with the OECD Guidelines for Testing of Chemicals (2010) No. 209 "Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation)".
Following a preliminary range-finding test, activated sewage sludge was exposed to an aqueous dispersion of the test item at concentrations of 180, 320, 560, 1000 and 1800 mg/L (3 replicates) for a period of 3 hours at measured temperatures of approximately 22 °C with the addition of a synthetic sewage as a respiratory substrate.
The rate of respiration was determined after 3 hours contact time and compared to data for the control and a reference item, 3,5-dichlorophenol.
The effect of the test item on the respiration of activated sewage sludge gave a 3-Hour EC50 value of 770 mg/L.
The reference item gave a 3-Hour EC50 value of 5.3 mg/L, 95% confidence limits 3.8 to 7.3 mg/L.
Reference
Description of key information
A study was performed to assess the effect of the test item on the respiration of activated sewage sludge. The method followed was designed to be compatible with the OECD Guidelines for Testing of Chemicals (2010) No. 209 "Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation)".
Following a preliminary range-finding test, activated sewage sludge was exposed to an aqueous dispersion of the test item at concentrations of 180, 320, 560, 1000 and 1800 mg/L (3 replicates) for a period of 3 hours at measured temperatures of approximately 22 °C with the addition of a synthetic sewage as a respiratory substrate.
The rate of respiration was determined after 3 hours contact time and compared to data for the control and a reference item, 3,5-dichlorophenol.
The effect of the test item on the respiration of activated sewage sludge gave a 3-Hour EC50 value of 770 mg/L.
The reference item gave a 3-Hour EC50 value of 5.3 mg/L, 95% confidence limits 3.8 to 7.3 mg/L.
Key value for chemical safety assessment
- EC50 for microorganisms:
- 770 mg/L
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.