Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Contact with:
powdered cellulose
Key result
Sample tested:
1:1 sample-to-cellulose ratio
Parameter:
burning rate
Remarks on result:
mixture does not ignite and burn

Full Train Test

 Ratio

Test Item : Cellulose

 Weight

Test Item (g)

 Weight

Cellulose (g)

Ignition time (sec) 
 10 : 90%  1.00  9.00  ignited but did not propagate
 20 : 80%  2.00  8.00  did not ignite
 30 : 70%  3.00  7.00   did not ignite 
 40 : 60%  4.00  6.00   did not ignite 
 50 : 50%  5.00 5.00    did not ignite 
 40 : 60%  6.00  4.00   did not ignite 
 30 : 70%  7.00  3.00   did not ignite 
 20 : 80% 8.00   2.00    did not ignite
 10 : 90% 13.50   1.50    did not ignite

 

Reference Test

 Ratio

Ba (NO3)2 : Cellulose

 Weight

Test Item (g)

 Weight

Cellulose (g)

Ignition time (sec) 
 10 : 90%  1.00  9.00 112
 20 : 80%  2.00  8.00 98
 30 : 70%  3.00  7.00 97
 40 : 60%  4.00  6.00 103
 50 : 50%  7.50 7.50  107
 40 : 60%  9.00  6.00 110 
 30 : 70%  10.50  4.50 119 
 20 : 80% 16.00  4.00 187
 10 : 90% 22.50  2.50 did not ignite
Interpretation of results:
GHS criteria not met
Conclusions:
This substance tested has no oxidising properties.

Description of key information

In an EU method, GLP-compliant study, the substance did not ignite or burn during the test and therefore the test item does not have oxidising properties.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification

The test item did not ignite or burn during the test and therefore the substance has no oxidising properties. The substance is not classified as an oxidising solid in accordamce with the CLP regulation (EC 1272/2008).