Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Charge Number: 30-19-A6-99906325
Key result
Flash point:
172 °C
Atm. press.:
1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point has been determined by the Pensky Martens by ASTM Method D93 as 172 °C (342°F).

Description of key information

The flash point has been determined by the Pensky Martens by ASTM Method D93 as 172 °C (342°F).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
172 °C

Additional information