Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 3 - December 19, 1998
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report Date:
1999

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Qualifier:
according to
Guideline:
other: OECD Guidelines 109
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: no ignition

Any other information on results incl. tables

In the preliminary test the sample tested does not ignite and it does not propagate combustion. No further testing will be required.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The sample tested does not ignite and it does not propagate combustion. DTZ62 has to be considered as not flammable substance.