Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point, other
Type of information:
(Q)SAR
Adequacy of study:
supporting study
Reliability:
3 (not reliable)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with limited documentation / justification
Justification for type of information:
information from database
Qualifier:
according to guideline
Guideline:
other: Calculated (ACD/Labs) Software V11.02
Type of method:
other: calculation
Flash point:
107.1 °C
Remarks on result:
other: no vapour pressure reported

The calculated value for the flash point is reported to 107.1+/-11.0 °C.

Conclusions:
The calculated value for the flash point is reported to 107.1+/-11.0 °C.
Executive summary:

The results were calculated with (ACD/Labs) Software V11.02 and are thus considered to be not reliable.

Endpoint:
flash point, other
Type of information:
not specified
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Justification for type of information:
information from database GESTIS
Guideline:
other: not specified
Deviations:
not applicable
Remarks:
not specified
GLP compliance:
not specified
Other quality assurance:
other: not specified
Type of method:
other: not specified
Flash point apparatus:
other: not specified
Specific details on test material used for the study:
not specified
Key result
Flash point:
126 °C
Remarks on result:
other: no vapour pressure reported

The value for the flash point is reported to 126 °C.

Conclusions:
The value for the flash point is reported to 126 °C.
Executive summary:

Although the test method is not reported, the data were taken from a peer-reviewed database and are thus considered to be reliable with restrictions.

Description of key information

The value for the flash point is reported to 126 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
126 °C

Additional information

Although the test method is not reported, the data were taken from a peer-reviewed database and are thus considered to be reliable with restrictions.