Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
gas saturation method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Vapour pressure
Key result
Temp.:
20 °C
Vapour pressure:
0.002 Pa

Applicant's summary and conclusion

Conclusions:
Vapour pressure of GR-86-6599: 0.002 Pa at 20°C
Executive summary:

The vapour pressure of the test material GR-86-6599 has been determined to be 0.002 Pa at 20°C using the gas saturation method.

 

Therefore:

Vapour pressure of GR-86-6599: 0.002 Pa at 20°C;