Registration Dossier

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1974
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1974
Report Date:
1974

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
OECD Guideline 405 (Acute Eye Irritation / Corrosion)
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder

Test animals / tissue source

Species:
rabbit
Strain:
New Zealand White
Details on test animals or tissues and environmental conditions:
Body weight at study initiation: 2.5 - 3.5 kg

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent no treatment
Amount / concentration applied:
100 mg
Observation period (in vivo):
7 d
Number of animals or in vitro replicates:
3
Details on study design:
REMOVAL OF TEST SUBSTANCE
- Time after start of exposure: no active removal

SCORING SYSTEM: Draize system

TOOL USED TO ASSESS SCORE: hand-slit lamp

Results and discussion

In vivo

Resultsopen allclose all
Irritation parameter:
cornea opacity score
Basis:
mean
Time point:
24/48/72 h
Score:
0
Max. score:
4
Remarks on result:
no indication of irritation
Irritation parameter:
iris score
Basis:
mean
Time point:
24/48/72 h
Score:
0
Max. score:
2
Remarks on result:
no indication of irritation
Irritation parameter:
conjunctivae score
Basis:
mean
Time point:
24/48/72 h
Score:
0
Max. score:
3
Remarks on result:
no indication of irritation
Irritation parameter:
chemosis score
Basis:
mean
Time point:
24/48/72 h
Score:
0
Max. score:
4
Remarks on result:
no indication of irritation
Irritant / corrosive response data:
none
Other effects:
none

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item caused no irritation in rabbit eyes at the beginning of the study. Therefore, the substance is not classifiable according to the CLP Regulation.