Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 25, 2004
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Remarks:
Burning rate 4 (Spread of a glowing fire) < 2,22 mm/s

Description of key information

The test item is non-flammable according to European Commission Regulation (EC) No. 440/2008, A.10. Flammability (solids) and UN Manual of test and criteria, rev.5, N.1 Test method for readily combustible solids

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification