Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
06.September 2017 - 07.September 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point apparatus:
other: Normalab NPV310
Dynamic viscosity of test material:
unknown

Test material

Constituent 1
Chemical structure
Reference substance name:
Fatty acids, C18 unsatd., reaction products with triethanolamine
EC Number:
938-513-5
Cas Number:
1187872-27-0
IUPAC Name:
Fatty acids, C18 unsatd., reaction products with triethanolamine
Test material form:
liquid: viscous
Specific details on test material used for the study:
Batch DEB2 207167

Results and discussion

Flash point
Flash point:
216.5 °C
Atm. press.:
1 013 hPa

Any other information on results incl. tables

Table 1: Preliminary test

 
 Test item / ml  Starting temperature / °C  Temperature / °C  Ignition + / -
 2  20.0  10  -
 4  100.0  250  -
 4  100.0  260  -
 4  100.0  218  +

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The lowest flash point corrected to 1013 hPa is rounded down with an accuracy of 0.5 °C: 216.5 °C.
Executive summary:

The lowest flash point corrected to 1013 hPa is rounded down with an accuracy of 0.5 °C: 216.5 °C according to the European Commission Regulation (EC) No. 440/2008, A.9. Flash point and ISO 3679:

Determination of flash-point – Rapid equilibrium closed cup method.