Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM Method D 56
GLP compliance:
yes
Type of method:
closed cup
Flash point:
> 99 °C
Atm. press.:
755.4 mm Hg

None observed when heated to 99°C

Interpretation of results:
GHS criteria not met
Conclusions:
No flash point observed when heated to 99°C
Executive summary:

The flash point of the test substance was determined by the ASTM Method D56 (Tag Closed Cup). No flash point observed when heated to 99°C.

Description of key information

ASTM Method D56

Key value for chemical safety assessment

Additional information

No flash point observed when heated to 99°C