Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-02-09 to 2017-03-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling Point)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
Qualifier:
according to
Guideline:
EPA OPPTS 830.7220 (Boiling Point / Boiling Range)
Deviations:
no
GLP compliance:
yes
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 506001
- Expiration date of the lot/batch: 2018-03-24

Results and discussion

Boiling point
Key result
Atm. press.:
ca. 1 atm
Decomposition:
yes
Remarks:
Decomposition occurred before boiling occured
Decomp. temp.:
ca. 245
Remarks on result:
not determinable

Applicant's summary and conclusion

Conclusions:
This substance has no boiling temperature as decomposition/reaction occurred before boiling of the substance could occur.