Administrative data

Link to relevant study record(s)

Description of key information

The experimental method used at Chilworth Technology Ltd. for vapour pressure determination was not suitable and the recommended ranges were inappropriate. Therefore, the study from Chilworth Technology Ltd.,  is considered to be Klimisch 2 reliability rating and it must be ignored.  
The following estimated vapour pressures at 20 °C and at 25 °C were calculated from the regression equation:
Vapour pressure at 20°C: 9.42 * 10-03 Pa
Vapour pressure at 25°C: 1.34 * 10-02 Pa

Key value for chemical safety assessment

Additional information