Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03 November 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2003
Deviations:
no
GLP compliance:
no
Remarks:
Study was not performed under GLP, however the test facility was GLP-compliant.
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
105.5 °C
Atm. press.:
>= 1 010.4 - <= 1 010.8 hPa
Remarks on result:
other: Average corrected flash point rounded down to the nearest multiple of 0.5 °C

Table 1. Main test results

 Amount of test item (g)  Temperature (°C)  Ignition (+/-)  Air pressure (hPa)  Flash point (corrected) (°C)
 60.71  106.0  +  1010.4  106.07
 60.97  105.0  +  1010.8  105.06
Interpretation of results:
GHS criteria not met
Conclusions:
The test item has a flash point of 105.5 °C at 1010 hPa.
Executive summary:

Flashpoint was determined by closed cup (Pensky Martens) method according to EU Method A.9 and DIN EN ISO 2719 (2017). The study was not performed under GLP, however the test facility was GLP-compliant. The study is considered to be reliable without restrictions (Klimisch 1). The flashpoint of the test item was determined to be 105.5°C at 1010 hPa.

Description of key information

The flashpoint of the test item was determined to be 105.5°C at 1010 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
105.5 °C

Additional information

Flashpoint was determined by closed cup (Pensky Martens) method according to EU Method A.9 and DIN EN ISO 2719 (2017). The study was not performed under GLP, however the test facility was GLP-compliant. The study is considered to be reliable without restrictions (Klimisch 1). The flashpoint of the test item was determined to be 105.5°C at 1010 hPa. With a measured flash point > 60°C, the test item does not have to be classified as flammable liquid according to GHS or CLP Regulation EC 1272/2008 Annex 1.