Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 484-360-8 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- August 03, 2007
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: The study has been performed according to OECD guidelines and according to GLP principles.
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
- Deviations:
- no
- Principles of method if other than guideline:
- ISO Standard 8192, Water Quality - Test for inhibition of oxygen consumption by activated sludge for carbonaceous and ammonium oxidation (2007).
- GLP compliance:
- yes
- Analytical monitoring:
- no
- Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Test type:
- other: aerobic
- Water media type:
- freshwater
- Limit test:
- yes
- Total exposure duration:
- 3 h
- Key result
- Duration:
- 3 h
- Dose descriptor:
- IC50
- Effect conc.:
- > 100 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Key result
- Duration:
- 3 h
- Dose descriptor:
- NOEC
- Effect conc.:
- 100 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Validity criteria fulfilled:
- yes
- Conclusions:
- Under the conditions of this present test, Reaction products of Fatty acids, C16-18 and C18-unsatd. and reaction mass of 1,3-alkanediol, 2-(hydroxymethyl)-2-[(methoxymethoxy)methyl]- and 1,3-heteromonocycle-5,5-dimethanol was not toxic to waste water (activated sludge) bacteria at the loading rate of 100 mg/l, the regulatory limit concentration.
Reference
Comments:
Under the conditions of this present test, the test
substance was not toxic to waste water (activated sludge)
bacteria at the loading rate of 100 mg/l, the regulatory
limit concentration.
Description of key information
The study was performed according to OECD Guideline 209 and GLP principles.
Key value for chemical safety assessment
- EC50 for microorganisms:
- 100 mg/L
- EC10 or NOEC for microorganisms:
- 100 mg/L
Additional information
The respiration rate of activated sludge was investigated according to OECD test guideline 209. The sludge was exposed to Radia 7853 with a contact time of 3 hours, at a final loading rate of 100 mg/l. No significant inhibition of respiration rate of the sludge was recorded at the loading rate of 100 mg/l, thus no further testing was required. Hence, the EC50 of Rqadia 7853 was >100 mg/l (nominal) and the NOEC was determined to be 100 mg/l.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
