Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 16 - October 13, 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
Principles of method if other than guideline:

ASTM International, ASTM D 93: "Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester", December 10, 2002.
GLP compliance:
yes
Type of method:
closed cup
Key result
Flash point:
200 °C
Atm. press.:
101.3 kPa

The flash-point of the test substance was determined using a
model APM-7 Pensky-Martens closed cup automatic flash-point
tester.

Conclusions:
The flash-point of the test substance was 200°C at 101.3 kPa.

Description of key information

The study was performed according to ISO Guide 2719/EU method A.9 and GLP principles.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
200 °C

Additional information