Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 0011440677

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: ambient temperature
Key result
Flash point:
174 °C
Atm. press.:
1 013.25 hPa

Initial test: 176.0 °C

1st Run: 175.2 °C*

2nd Run: 173.2°C*

* Corrected flash point

Interpretation of results:
GHS criteria not met

Description of key information

174 °C at 1013.25 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
174 °C

Additional information

A study was conducted according ISO 2719 to determine the flash point of the test item using a Pensky-Martens apparatus. The flash point of the test item was determined to be 174 °C at 1013.25 hPa (BASF SE SIK 15/2193).