Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
no
Type of method:
other: Ubbelohde viscometer

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Viscosityopen allclose all
Key result
Temp.:
other: 25 °C
Parameter:
dynamic viscosity (in mPa s)
Value:
9.79
Temp.:
other: 25 °C
Parameter:
other: kinematik viscosity (m2/s)
Value:
0

Any other information on results incl. tables

Result/Calculation

Temperature: 25 °C

Apparatus: Ubbelohde viscometer (Viscometer constant 0.175 cSt/s)

Flow Time: (1) 49.20 sec, (2) 49.56 sec, (3) 49.62 sec, average 49.46 sec

Kinematic Viscosity 0.175 × 49.46 = 8.66 cSt = 8.66×10-6 m2/s

Dynamic viscosity 8.66 cSt × 1.13 g/cm3 = 9.79 cP = 9.79 mPa・s

Applicant's summary and conclusion