Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January 1990 - April 2015, 27 April 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Principles of method if other than guideline:
Tagliabue closed cupCleveland open cup test
GLP compliance:
no
Type of method:
other: closed cup and open cup
Flash point apparatus:
other: Tagliabue closed cup; Cleveland open cup test

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Flash pointopen allclose all
Key result
Flash point:
147 °C
Atm. press.:
101.325 kPa
Remarks on result:
other: open cup
Remarks:
The flash point temperature was corrected to a pressure of 101.325kPa
Remarks on result:
other: closed cup, no flash was observed up 83 °C

Any other information on results incl. tables

Closed cup: No flash was observed up to 83 °C (atmospheric pressure 92.8 kPa).

Applicant's summary and conclusion