Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1999-12-17 to 2000-03-21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Sponsor and R90076
- Expiration date of the lot/batch: 2000-07-31

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature in the dark
Key result
Type:
relative density
Density:
ca. 1.19 g/cm³
Temp.:
24 °C
Conclusions:
This study validly assessed the realtive density of the test substance according to the specified guidelines.

Description of key information

The relative density of BMS 233101-01 was found to be 1.19 g/cm³

Key value for chemical safety assessment

Relative density at 20C:
1.19