Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 13736 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Abel apparatus

Test material

Constituent 1
Reference substance name:
Hexamethyldisiloxane
EC Number:
203-492-7
EC Name:
Hexamethyldisiloxane
Cas Number:
107-46-0
Molecular formula:
C6H18OSi2
IUPAC Name:
Hexamethyldisiloxane
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
-5 °C
Atm. press.:
1 013.25 hPa

Applicant's summary and conclusion