Administrative data

First-aid measures

4.1 Description of first aid measures

· General information:

Get medical advice/attention if you feel unwell.

Immediately remove any clothing soiled by the product.

Take affected persons out of danger area and lay down.

· After inhalation:

Supply fresh air and to be sure call for a doctor.

In case of unconsciousness place patient stably in side position for transportation.

· After skin contact: Immediately wash with water and soap and rinse thoroughly.

· After eye contact:

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

· After swallowing: Call for a doctor immediately.

· 4.2 Most important symptoms and effects, both acute and delayed Illness

· 4.3 Indication of any immediate medical attention and special treatment needed

Treat symptomatically.

For specialist advice physicians should contact the Poisons Information Service.

Fire-fighting measures

· 5.1 Extinguishing media

· Suitable extinguishing agents:

CO₂, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

· For safety reasons unsuitable extinguishing agents: Water with full jet

· 5.2 Special hazards arising from the substance or mixture

During heating or in case of fire poisonous gases are produced.

Sulphur dioxide (SO₂)

· 5.3 Advice for firefighters

· Protective equipment:

Wear self-contained respiratory protective device.

Do not inhale explosion gases or combustion gases.

Accidental release measures

· 6.1 Personal precautions, protective equipment and emergency procedures

Avoid formation of dust.

Wear protective clothing.

· 6.2 Environmental precautions: Do not allow to enter sewers/ surface or ground water.

· 6.3 Methods and material for containment and cleaning up:

Pick up mechanically.

Ensure adequate ventilation.

Dispose contaminated material as waste according to item 13.

· 6.4 Reference to other sections

See Section 7 for information on safe handling.

See Section 8 for information on personal protection equipment.

See Section 13 for disposal information.

Handling and storage

· 7.1 Precautions for safe handling

Prevent formation of dust.

Ensure good ventilation/exhaustion at the workplace.

Use appropriate industrial vacuum cleaners or central vacuum systems for dust removal.

Dust can combine with air to form an explosive mixture.

· Information about fire - and explosion protection:

Keep ignition sources away - Do not smoke.

Protect against electrostatic charges.

· 7.2 Conditions for safe storage, including any incompatibilities

· Storage:

· Requirements to be met by storerooms and receptacles: Store only in the original receptacle.

· Information about storage in one common storage facility: Do not store together with acids.

· Further information about storage conditions:

Keep container tightly sealed.

Store in dry conditions.

· 7.3 Specific end use(s)

Additive for composites.

Additive for lubricants

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

· Additional information about design of technical facilities:

local ventilation

No further data; see item 7.

· 8.1 Control parameters

· Ingredients with limit values that require monitoring at the workplace: Not required.

· Additional information: The lists valid during the making were used as basis.

· 8.2 Exposure controls

· Personal protective equipment:

· General protective and hygienic measures:

The usual precautionary measures are to be adhered to when handling chemicals.

Do not inhale dust / smoke / mist.

Keep away from foodstuffs, beverages and feed.

Wash hands before breaks and at the end of work.

Use skin protection cream for skin protection.

· Respiratory protection:

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer

exposure use self-contained respiratory protective device.

Short term filter device:

Filter P2

· Protection of hands:

Protective gloves

The glove material has to be impermeable and resistant to the product/ the substance/ the

preparation.

Use gloves of stable material (e.g. Nitrile) - if necessary tricoted to improve the wearability.

· Material of gloves

Nitrile rubber, NBR

Recommended thickness of the material:  0,2 mm

· Penetration time of glove material

The exact break through time has to be found out by the manufacturer of the protective gloves and

has to be observed.

· Eye protection: Safety glasses

· Body protection: Protective work clothing

Stability and reactivity

· 10.1 Reactivity No further relevant information available.

· 10.2 Chemical stability

· Thermal decomposition / conditions to be avoided:

To avoid thermal decomposition do not overheat.

· 10.3 Possibility of hazardous reactions

With strong oxidizing agents formation of sulphur dioxide

With concentrated acids formation of hydrogen sulphide

· 10.4 Conditions to avoid No further relevant information available.

· 10.5 Incompatible materials:

strong acids

strong oxidizing agents

· 10.6 Hazardous decomposition products:

Sulphur dioxide

Hydrogen sulphide

Disposal considerations

· 13.1 Waste treatment methods

· Recommendation Disposal must be made according to official regulations

· European waste catalogue

06 06 02 wastes containing dangerous sulphides

· Uncleaned packaging:

· Recommendation: Disposal must be made according to official regulations.