First-aid measures

INHALATION : If you feel unwell, remove to fresh air immediately. Get medical attention if cough or other symptoms develop.

EYE CONTACT : Immediately flush eyes with plenty of water for several minutes. Part eyelids with fingers to assure complete flushing. Check for and    remove contact lenses if easily possible. Get medical attention if irritation persists.

SKIN CONTACT : Immediately remove contaminated clothing and shoes. Flush skin with large amounts of water, clean off with soap and water. Get        medical attention if symptoms develop.

INGESTION :

Do NOT induce vomiting. Rinse mouth with water. Never give anything by mouth to an unconscious person. Keep the affected person warm and at       rest. Get medical attention immediately.

Fire-fighting measures

EXTINGUISHING MEDIA: water fog, foam, dry chemical, CO2, dry sand.

Initial fire: dry chemical, CO2, dry sand.

Large fire: water fog or foam.

UNSUITABLE EXTINGUISHING MEDIA: Do not use water jet to fight fire. Water fog may be used to cool containers.

FLAMMABLE PROPERTIES :Can burn in fire. May catch fire or explode if heated.

FIRE FIGHTING INSTRUCTIONS:

Keep unnecessary and unprotected personnel away. Shut off supply if possible. Remove containers to safe place if possible. Keep surrounding areas  cool by spraying water. Fight fire from an upwind position.

FIRE FIGHTING EQUIPMENT:

Respiratory and eye protection required for fire-fighting personnel. Full protective equipment and self-contained breathing apparatus (SCBA) should be used for all indoor fires and any significant outdoor fires.

HAZARDOUS COMBUSTION PRODUCTS: Carbon oxides.

Accidental release measures

PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES: Keep unnecessary and unprotected personnel away. Wear

appropriate personal protective equipment as specified in Section 8. Keep upwind, evacuate downwind.

ENVIRONMENTAL PRECAUTIONS: Do not flush into sewer, river or any body of water.

CONTAINMENT/CLEAN-UP METHODS: Absorb or cover with dry earth, sand or other non-combustible material and transfer to sealable containers. Large spills: Dike far ahead of liquid spill for later disposal. Stop leak if possible without personal risk. Avoid runoff to sewers or waterways.

Handling and storage

HANDLING

Technical Measures: Use only in well-ventilated area. Keep away from heat, sparks, and flame. Use explosion-proof electrical

equipment and take precautions against build-up of electrostatic charges as necessary. Avoid contact with eyes, skin, and clothing. Avoid

ingestion and inhalation. Wear appropriate personal protective equipment. Provide hand and eye wash station near work area. Wash thoroughly after handling.

Ventilation: Use only under local exhaust or general ventilation.

Safe Handling Advice: Do not handle until all safety precautions have been read and understood. Prevent leak and spill. Avoid vapor formation. Do not fall, drop, shock or drag container. Avoid contact with eye, skin or clothing. Avoid inhalation and ingestion. Use only in well-ventilated area or             outdoors.

Storage Conditions: Keep container tightly closed. Protect from direct sunlight. Store in well-ventilated area.

Packaging Material: Use containers approved by local and national authorities.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

ENGINEERING CONTROLS :Provide general ventilation. Use closed system or local exhaust ventilation. Provide safety shower and eye wash

station near work area.

PERSONAL PROTECTIVE EQUIPMENT

Respiratory protection : Chemical cartridge respiratorwith organic vapor cartridge.

Hand protection : Protective gloves.

Eye protection : Safety glasses, goggles, faceshield.

Skin and body protection : Safety helmet, protective clothing, safety boots, apron.

Stability and reactivity

STABILITY : Stable for normal storage and handling.

HAZARDOUS REACTIONS : Reacts with strong oxidizers, strong acids, strong bases.

CONDITIONS TO AVOID : Heat, overheating.

MATERIALS TO AVOID : Oxidizers.

HAZARDOUS DECOMPOSITION PRODUCTS: Carbon oxides.

Disposal considerations

WASTE FROM RESIDUES :

Whatever cannot be saved for recovery may be burned in an approved incinerator or disposed in approved waste facility.

Ensure compliance with local, state, federal and national regulations.

CONTAMINATED PACKAGING :Empty the container completely before disposal.