Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-09-01
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. certificate)

Preliminary test:

During the ignition no independent burning or glowing over the length of the pile was observed in the preliminary test (with a gas burner) according to EU Method A.10 (Flammable solid).

The part of the test item which had direct contact with the ignition source and which was melted, became viscous with a beige colour.

The main test was not performed because no burning or glowing over the length of the pile was observed in the preliminary test.

Interpretation of results:
not classified based on GHS criteria
Remarks:
not classified based on CLP criteria
Conclusions:
During the ignition no independent burning or glowing over the length of the pile was observed in the preliminary test (with a gas burner) according to EU Method A.10 (Flammable solid).
The test item does not have to be classified as “flammable solid” according to EC Regulation No. 1272/2008.

Description of key information

During the ignition no independent burning or glowing over the length of the pile was observed in the preliminary test (with a gas burner) according to EU Method A.10 (Flammable soild).

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification