Endpoint:
nanomaterial dustiness
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26 June 2020 to 17 July 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EN 15051-2 (Workplace exposure. Measurement of the dustiness of bulk materials - Rotating drum method)
Deviations:
no
GLP compliance:
not specified
Type of method:
rotating cylinder
Sampling:
Sample amount: 14 g
Each sample has been divided in eight equal lots using a rotary riffler, this rotary riffler is especially designed to minimize the loss of any fine dust. One of these divided lots has been used for determining the bulk density and the moisture content.

Test material

Constituent 1
Chemical structure
Reference substance name:
Xanthylium, 9-[2-(ethoxycarbonyl)phenyl]-3,6-bis(ethylamino)-2,7-dimethyl-, molybdatesilicate
EC Number:
263-793-4
EC Name:
Xanthylium, 9-[2-(ethoxycarbonyl)phenyl]-3,6-bis(ethylamino)-2,7-dimethyl-, molybdatesilicate
Cas Number:
63022-06-0
Molecular formula:
Not applicable as the substance is UVCB
IUPAC Name:
reaction products of ethyl 2-[3-(ethylamino)-6-ethylimino-2,7-dimethylxanthen-9-yl]benzoate with silicomolybdic acid
Test material form:
solid: nanoform
Details on test material:
Shape
Shape Category: spheroidal
Shape: spherical
Pure Shape: Yes
Typical Composition: ≤100%
range: >0; ≤100%

Particle size distribution & range
Shape Category: spheroidal
Percentile D10, typical value: 35nm
Percentile D10, range: ≥10; ≤50nm
Percentile D50, typical value: 50nm
Percentile D50, range: ≥35; ≤100nm
Percentile D90, typical value: 85nm
Percentile D90, range: ≥50; ≤150nm
Fraction in size range 1-100nm: ≥50; ≤100%

Crystallinity
structure: Amorphous
Pure structure: Yes

Specific Surface Area
Typical specific surface area: ca. 45m2/g
Range: ≥10; ≤200m2/g
Skeletal density: ca. 1,8 g/cm3

Surface Functionalisation/treatment
surface treatment applied: no
Specific details on test material used for the study:
Sample material: Lumière Pink S.M.
Sample ID: 8135N
Batch Number: 021340
Supplier: Ferro Performance Pigments Belgium NV, Belgium

Data gathering

Instruments:
The health related dustiness investigations have been performed using the 15051 rotating drum dustiness tester according to the European standard

Results and discussion

Dustiness index
Remarks on result:
other: dustiness mass fractions determined

Any other information on results incl. tables

Summary of the dustiness data of sample Lumière Pink S.M. 8135N 021340 according to EN 15051, measured at a relative humidity of 48 %.





























































 Sample massInhalable fractionThoracic fractionRespirable fraction
gmgmg/kgmg  mg/kgmgmg/kg
1st test13.7182218.915954

33.6



2446



4.4



318



2nd 



13.5742



196.9



14503



28.3



2089



6.0



443



3rd



13.5632



211.6



15603



30.5



2250



4.8



356



Average



 



 



15353



 



2262



 



372



 


Moisture content: 2.45 %


Bulk density: 353.2 kg m-3


 


It can be concluded based on the RSD values of the inhalable and thoracic fractions (≤15 %) that the dustiness potentials of the independent triplicates are highly repeatable. The higher RSD for the respirable fraction is caused by the lower absolute masses of the dust fractions or inhomogeneity of the samples.

Applicant's summary and conclusion

Conclusions:
The fraction of constituent particles with an aerodynamic diameter <10µm in Lumière Pink S.M. 8135N is <1%.
Executive summary:

The dustiness of Lumière Pink S.M. 8135N was determined by EN 15051 - Rotating drum (method 2).


Results are shown below.





























































 Sample massInhalable fractionThoracic fractionRespirable fraction
gmgmg/kgmg  mg/kgmgmg/kg
1st test13.7182218.915954

33.6



2446



4.4



318



2nd 



13.5742



196.9



14503



28.3



2089



6.0



443



3rd



13.5632



211.6



15603



30.5



2250



4.8



356



Average



 



 



15353



 



2262



 



372