Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study conducted following ASTM D93 16a Procedure
Qualifier:
according to
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
Procedure A
Deviations:
no
GLP compliance:
no
Remarks:
conducted under good manufacturing practices (GMP)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Remarks on result:
no flash point according to standard method
Remarks:
Flame extinguished 176°F, No flash observed
Interpretation of results:
study cannot be used for classification
Conclusions:
Not able to determined flash point using ASTM D93 Procedure A. Flame extinguished 176°F and no flash observed.

Description of key information

Not able to determine flash point using ASTM D93 Procedure A. Flame extinguished at 176°F and no flash was observed.

Key value for chemical safety assessment

Additional information