Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin sensitisation

Currently viewing:

Administrative data

Endpoint:
skin sensitisation: in vitro
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
March 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 442D (In Vitro Skin Sensitisation: ARE-Nrf2 Luciferase Test Method)
Deviations:
no
Principles of method if other than guideline:
Although the in vitro test was not carried out in a registered GLP laboratory, the Givaudan in vitro Technologies laboratory based at it's Dubendorf site in Switzerland performs all in vitro studies within the "spirit" of GLP. In addition this Givaudan laboratory at Dubendorf devised the KeratinoSens testing protocol and instigated the assay acceptance with ECHA and the OECD. The Givaudan laboratory at Dubendorf also was a member of the DPRA acceptance testing program of laboratories and has over 4 years experience with both the KeratinoSens and DPRA assays.
GLP compliance:
no
Remarks:
Although the in vitro test was not carried out in a registered GLP laboratory, the Givaudan in vitro Technologies laboratory based at it's Dubendorf site in Switzerland performs all in vitro studies within the "spirit" of GLP.
Type of study:
activation of keratinocytes
Justification for non-LLNA method:
A combination of two in-vitro skin sensitization tests is considered to be sufficient to conclude on the skin sensitization potential of Jasmonyl LG.

Test material

Constituent 1
Chemical structure
Reference substance name:
Tetrahydro-3-pentyl-2H-pyran-4-yl acetate
EC Number:
242-640-5
EC Name:
Tetrahydro-3-pentyl-2H-pyran-4-yl acetate
Cas Number:
18871-14-2
Molecular formula:
C12H22O3
IUPAC Name:
3-O-acetyl-1,5-anhydro-2,4-dideoxy-2-pentylpentitol
Constituent 2
Chemical structure
Reference substance name:
3-butyltetrahydro-5-methyl-2H-pyran-4-yl acetate
EC Number:
253-863-2
EC Name:
3-butyltetrahydro-5-methyl-2H-pyran-4-yl acetate
Cas Number:
38285-49-3
Molecular formula:
C12H22O3
IUPAC Name:
3-O-acetyl-1,5-anhydro-2-butyl-2,4-dideoxy-4-methylpentitol
impurity 1
Reference substance name:
3-pentyltetrahydro-2H-pyran-4-ol
Cas Number:
24646-98-8
Molecular formula:
C10H20O2=
IUPAC Name:
3-pentyltetrahydro-2H-pyran-4-ol
impurity 2
Reference substance name:
Likely acetylated constituents, MW 214
Molecular formula:
n/a
IUPAC Name:
Likely acetylated constituents, MW 214
impurity 3
Reference substance name:
Likely acetylated constituents
Molecular formula:
n/a
IUPAC Name:
Likely acetylated constituents
impurity 4
Reference substance name:
Unknown constituent, MW 172
Molecular formula:
n/a
IUPAC Name:
Unknown constituent, MW 172
Test material form:
liquid
Details on test material:
UVCB substance
Specific details on test material used for the study:
Batch number: PE00138468

In vitro test system

Details on the study design:
The KeratinoSensTM assay is a cell-based assay with a reporter cell line to detect potential skin sensitizers by their ability to induce the Nrf2-response.
This assay has been validated for a broad range of low-molecular weight chemicals and it was found to respond to skin sensitizers from a broad range of so called applicability domains, i.e. chemicals reacting with proteins by different mechanisms. It was validated by ECVAM and proposed to be used as part of an integrated approach for testing and assessment (IATA).

Results and discussion

Positive control results:
Postiive control: Cinnamic aldehyde

In vitro / in chemico

Results
Key result
Value:
1
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of skin sensitisation

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Executive summary:

In all three repetitions, no induction of the luciferase above the threshold of 1.5 was noted. According to the prediction model of the KeratinoSens™ assay, the test substance is rated as non-sensitizer. This conclusion is also clearly supported by the analysis of the dose-response curve in Figure 4 with overall no induction of the luciferase reporter gene to be observed.