Registration Dossier

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

General advice:  Take the victim out of the contaminated area. Remove contaminated clothing immediately and dispose of safely.  

If inhaled:  Move to fresh air. Make the victim blow his nose. Seek medical advice.  

In case of skin contact: Rinse immediately with plenty of water for at least 15 minutes. Seek medical advice.  

In case of eye contact:  Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Seek medical advice.  

If swallowed: Do not induce vomiting. Make the victim rinse his mouth with water. Seek medical advice immediately.  

Most important symptoms and effects, both acute and delayed

Symptoms: Irritations.

Fire-fighting measures

Extinguishing media:  

Suitable extinguishing media : All means (e.g. water, carbon dioxide, dry chemical extinguisher).

Unsuitable extinguishing media:  Strong water jet.

Special hazards arising from the substance or mixture:

In case of fire, the product may emit toxic and/or irritating fumes.

Supposed thermal decomposition/oxidation:

Carbon monoxide and carbon dioxide

Advice for firefighters:  

Special protective equipment : Use self-contained breathing apparatus. Wear full protective suit.  

Further information : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Avoid discharging extinguishing water in the environment.  

Accidental release measures

Personal precautions, protective equipment and emergency procedures:

Particle full face respirator or powered air purifying respirator. Suitable gloves. Dedicated work clothes.  

Environmental precautions:

Avoid any spreading of the product.  

Methods and materials for containment and cleaning up:  

General advice: Sweep and shovel the solid product into a container specially adapted for its recovery or destroying (avoiding dust formation). Close and label thoroughly.  

Cleaning of contaminated zone:  After cleaning up the product, rinse the polluted area with water.

Elimination of recovered materials:  Deliver to the Environmental service of the factory or to any specialized and approved disposal company.

Reference to other sections:

Additional advice:

Evacuation of area and intervention of special services recommended.  

Handling and storage

Precautions for safe handling:

Advice on safe handling (industrial scale): Local ventilation and emission point dust extraction. Enclosed transfer recommended.  

Take precautionary measures against electrostatic loading. Earth vessels and equipment well.  

Advice on safe handling :  Handling in a hood.  

(laboratory scale)

Sensitivity:  No particular observation.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Industrial workplace

Respiratory protection: Particle full face mask or powered-air purifying respirator.

Hand protection: Suitable gloves.

Glove material:  Nitrile rubber

Layer thickness: 0,11 mm

Break through time:   > 480 min

Eye/face protection : See respiratory protection.

Body Protection:  Dedicated working clothes recommended.

Hygiene measures: Wash hands.  

Laboratory

Respiratory protection: Handling in a hood.

Hand protection: Suitable gloves.  

Eye/face protection: Safety glasses.

Body Protection: Working clothes.

Hygiene measures: Wash hands.  

Stability and reactivity

Safety remarks :     Dust may be explosive (no data available).

Reactivity  : No data available.  

Chemical stability  : No data available.  

Possibility of hazardous reactions : No data available.

Conditions to avoid  : No data available.  

Incompatible materials  : Strong oxidizing agents.

Hazardous decomposition products :  

Supposed thermal decomposition/oxidation:

Carbon monoxide and carbon dioxide

Disposal considerations

Waste treatment methods:

Product: Deliver to the Environmental service of the factory or to any specialized and approved disposal service.

Uncleaned packaging: Deliver to the Environmental service of the factory or to any specialized and approved disposal service.

Categories Display