Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
not specified
Type of method:
closed cup
Key result
Flash point:
168.5 °C
Atm. press.:
1 013 hPa
Conclusions:
The flash point of the test substance was 168.5°C.
Executive summary:

A study was conducted to determine the flash point of the test substance according to EU Method A.9 and ISO 2719:2000 (Pensky-Martens closed cup method). Under the study conditions, the flash point of the test substance was 168.5°C (Sohar C, 2015).

Description of key information

The flash point was determined according to EU Method A.9 (Sohar, 2015).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
168.5 °C

Additional information