Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes
Type of method:
spinning rotor

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Purity: 99.83%

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
0.108 Pa

Applicant's summary and conclusion

Conclusions:
The vapour pressure of the test substance is 0.108 Pa at 20°C.
Executive summary: