Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid
Details on test material:
No other details on test material were provided.
Specific details on test material used for the study:
No other specific details were provided.

Results and discussion

Flash point
Key result
Flash point:
ca. 67 °C
Remarks on result:
other: Flash point of the test material is determined to be 66 °C

Applicant's summary and conclusion

Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
The flash point of 3-bromopyridine was determined to be 67°C using ISO 2719:2002 method.
Executive summary:

The flash point of 3-bromopyridine was determined to be 67°C using ISO 2719:2002 method.