Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 June 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D445-10 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity)
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)
Key result
Temp.:
other: 100.0°C
Parameter:
other: cSt
Value:
5.197
Conclusions:
Viscosity was determined to be 5.197 cSt at 100 °C.
Executive summary:

The viscosity of the test material was determined according to the procedures given in ASTM D445-10 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity). The viscosity result was 5.197 cSt at 100 °C.

Description of key information

Viscosity result was determined to be 5.197 cSt at 100 °C (ASTM D445-10 ).

Key value for chemical safety assessment

Viscosity:
5.197 mm²/s (static)
at the temperature of:
100 °C

Additional information

The viscosity of the test material was determined according to the procedures given in ASTM D445-10 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity). The viscosity result was 5.197 cSt at 100 °C.