Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental result performed using standard methods of analysis
Qualifier:
according to guideline
Guideline:
ISO No., other: OECD 103
Principles of method if other than guideline:
The flash point of a substance is the lowest temperature at which there will be enough flammable vapor to ignite when an ignition source is applied.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Name of test material : sulfoacetic acid
- Molecular formula : C2H4O5S
- Molecular weight : 140.115 g/mol
- Smiles notation : S(CC(O)=O)(O)(=O)=O
- InChl : 1S/C2H4O5S/c3-2(4)1-8(5,6)7/h1H2,(H,3,4)(H,5,6,7)
- Substance type:Organic
- Physical state:Solid
Key result
Flash point:
128 °C
Atm. press.:
966 hPa
Remarks on result:
other: no other details available
Conclusions:
The flash point determination of chemical sulfoacetic acid was done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test substance determined to be 128 °C at 966 hPa
Executive summary:

The flash point determination of chemical sulfoacetic acid was done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test substance determined to be 128 °C at 966 hPa

Description of key information

The flash point determination of chemicalsulfoacetic acidwas done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test substance determined to be 128 °C at 966 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
128 °C

Additional information

The flash point determination of chemicalsulfoacetic acidwas done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test substance determined to be 128 °C at 966 hPa