Registration Dossier

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 105 (Water Solubility)
Qualifier:
according to
Guideline:
EU Method A.6 (Water Solubility)
Qualifier:
according to
Guideline:
EPA OPPTS 830.7840 (Water Solubility)
GLP compliance:
yes (incl. certificate)
Type of method:
flask method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Type:
impurity
Type:
impurity
Type:
impurity
Specific details on test material used for the study:
Commercial Name: Irone Alpha
Givaudan Code No.: 66065003
Aspect: pale yellow to pale amber liquid
Lot No.: VE00466614
Expiration date: March 29, 2019

Results and discussion

Water solubility
Water solubility:
32.5 mg/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
7

Applicant's summary and conclusion

Conclusions:
The solubility of Irone Alpha in ultrapure water was determined according to the OECD Guideline No. 105 (flask method).

The result is: Solubility in water: 32.5 mg/l at 20 °C

This result corresponds to the saturation mass concentrations of Irone Alpha in ultrapure water at 20 °C.