General information: Take the victim out of the contaminated area. Remove contaminated clothing immediately and dispose of safely.
Inhalation: Make the victim breathe fresh air. Make the victim blow his nose. Seek medical advice.
Skin contact: Rinse immediately with plenty of water for at least 15 minutes. Seek medical advice.
Eye contact: Rinse immediately with plenty of water for at least 15 minutes. Seek medical advice.
Ingestion: Do NOT induce vomiting. Make the victim rinse his mouth with water. Seek immediately medical advice

Fire-fighting measures

Suitable extinguishing media: All means (e.g. water, carbon dioxide, dry chemical extinguisher).
Extinguishing media that must not be used for safety reasons: Strong water jet.
Specific hazards: In case of fire, the product may emit toxic and/or irritating fumes. Supposed thermal decomposition/oxidation: Carbon monoxide and carbon dioxide; I2.
Protection during intervention: Use self-contained breathing apparatus. Wear full protective suit.
Further information: Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Avoid rejection of extinguishing water in the environment.

Accidental release measures

Personal precautions: Particle full face respirator or powered air purifying respirator. Suitable gloves. Dedicated work clothes.
Environmental precautions: Avoid spreading of product.
Methods for cleaning up/taking up: Sweep and shovel the solid product in a container adapted for its recovery or destroying (avoiding dust formation). Close and label rigorously.
Cleaning of contaminated zone: After taking up the product, rinse the polluted area with water.
Elimination of recovered materials: Deliver to Environmental service of the factory or to any specialized and approved disposal service.
Further information: Evacuation of area and intervention of special services recommended. Intervention of special services recommended.

Handling and storage

Sensitivity: No particular observation

Handling
Advice on safe handling (workshop): Local ventilation and emission point dust extraction. Take precautionnary measures against electrostatic loading. Earth vessels and equipment well.
Advice on safe handling (laboratory): Handling in a hood recommended.

Storage
Storage requirements: Keep in a cool, well-ventilated place.
Storage temperature: Keep at ambient temperature.
Incompatible materials: Keep away from strong oxidizers.

Further information on storage conditions: Keep in well closed container, away from light.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Threshold limit values and hazard class
ACGIH for powders not otherwise specified: 3 mg/mc respirable fraction, 10 mg/mc inhalable fraction.
OEL (EU) for Methanol: TWA/8h: 260 mg/m3; 200 ppm - SKIN.

Respiratory protection: Particle full face mask or powered-air purifying respirator (P1, P2 or P3)
Hand protection: Suitable gloves.
Glove material : Nitrile rubber
Layer thickness : > 0,12 mm
Permeation time : > 480 min
The protective gloves to be used must comply with the specifications of EC directive 89/686/EEC and standard EN374
Eye protection: See respiratory protection.
Body protection: Work clothes.
Hygiene measures: Wash hands.

Stability and reactivity

Hazardous reactions: reacts with strong oxidizers
Stable in normal storage conditions.
Hazardous decomposition products: Supposed thermal decomposition/oxidation: Carbon monoxide and carbon dioxide; I2.

Disposal considerations

Disposal Recommendations
Collect for recycling or recovery if possible. The recommended method of disposal is incineration.
Wherever possible, disposal should be in an on-site licenced chemical incinerator, if allowed by
the incinerator licence or permit. If no on-site incinerator is available, dispose of material in a
licenced commercial chemical incinerator.
All packages must be accurately washed before disposal, and disposed as unused product.
Regulatory Requirements