Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental Starting Date: 03/16/2016 - Experimental Completion: 03/16/2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
other: not specified
Type of distribution:
other: laser diffraction method with dry dispersion
Mass median aerodynamic diameter:
268.266 µm
Key result
Percentile:
other: L10
Mean:
14.636 µm
Remarks on result:
other: St. dev. not specified
Key result
Percentile:
other: L90
Mean:
687.266 other:
Remarks on result:
other: St. dev. not specified
Conclusions:
The median particle size (L50) of FAT 36002 was determined to be 268.266 µm.
Executive summary:

The particle size of FAT 36002 was determined in a study conducted according to the guidelines CIPAC MT 187 and ISO 13320 -1. Lased diffraction method was used for this purpose. Based on the findings of the study, L10, L50 and L90 for the test substance were determined to be 14.636, 268.266 and 687.021 µm, respectively. Hence, the median particle size (L50) of FAT 36002 was determined to be 268.266 µm.

Description of key information

The median particle size (L50) of FAT 36002 was determined to be 268.266 µm.

Additional information

The particle size of FAT 36002 was determined in a study conducted according to the guidelines CIPAC MT 187 and ISO 13320 -1. Lased diffraction method was used for this purpose. Based on the findings of the study, L10, L50 and L90 for the test substance were determined to be 14.636, 268.266 and 687.021 µm, respectively. Hence, the median particle size (L50) of FAT 36002 was determined to be 268.266 µm.